Titanium Braze 590

TiBraze-590 is a corrosion resistant filler metal suitable for brazing titanium, niobium, refractory metals, aluminides and stainless steels. It can also be used to join ceramics, graphite and carbon composites to metals and other non-metallic components without the need for prior metallization of the contact surface. Joints brazed with TiBraze-590 can be used in service temperatures up to 1022°F (550°C) for long term exposure.

Available Forms

Amorphous foil and specialty preforms per customer specifications

Characteristics

Suitable for use in all vacuum brazing applications as well as under partial pressure of argon gas. Brazing of alloys containing active components under protective nitrogen atmosphere is not recommended. It is important to maintain a high purity, oxygen-free environment; any oxidation of reactive elements will limit alloy wettability across the non-metallic surface. A vacuum of 10-4 torr or better is required to successfully braze with TiBraze-590. For controlled atmosphere brazing or vacuum brazing the recommended radial joint clearance for active alloys ranges between 0-0.002 in (0-0.05 mm).

Properties

The properties of a brazed joint are dependent upon the base metal, joint design and brazing technique. Below are several examples of shear strengths recorded for joints brazed wit TiBraze-590: Base Metal Titanium Grade 2 Ti-6Al-4V Titanium to Stainless Titanium to Copper Titanium to Nickel-lated Steel Shear Strength Titanium Grade 2: 200-235 MPa Ti-6Al-4V: 180-207 MPa Titanium to Stainless: 62-97 MPa Titanium to Copper: 83-110 MPa Titanium to Nickel-plated Steel: 95-124 MPa

Specs

Solidus

1465 F / 796 C

Liquidus

1495 F / 813 C

Disclaimer

The information and recommendations contained in this publication have been provided without charge & compiled from sources believed to be reliable and to represent the best information available on the subject at the time of issue. No warranty, guarantee, or representation is made by the Prince and Izant Company, Inc. as to the absolute correctness or sufficiency of any representation contained in this and other publications; Prince and Izant Company, Inc. assumes no responsibility in connection therewith; nor can it be assumed that all acceptable safety measures are contained in this (and other publications, or that other or additional measures may not be required under particular or exceptional conditions or circumstances.

Titanium Braze 590

Download TDS

Resources Center

We work closely with our customers to provide guidance and support on brazing and medical precious metal related issues.